Original Source Standard: Kalekim Giydirme Cephe Seramik Çözümleri. Bespoke dimensions, specifications, and certified configurations provided per project schedule.
Technical Catalogue / CB-FC-0103
Ventilated Curtain Wall Porcelain Cladding System
Rear-ventilated rainscreen cladding assembly utilizing ultra-thin sintered porcelain slabs (Kalesinterflex) bonded to extruded aluminium subframe carriers.
| Product Reference | CB-FC-0103 |
|---|---|
| System Architecture | Rear-ventilated thermal rainscreen curtain wall |
| Panel Technology | Ultra-slim 3mm / 5mm / 6mm mesh-backed sintered ceramic slabs |
| Carrier Profile Alloy | Extruded aluminium 6063-T6 architectural subframe grid |
| Structural Bonding Agent | 1401 Technobond PU single-component elastic structural adhesive |
| Air Cavity Depth | Minimum 50 mm continuous unobstructed ventilated cavity |
| Thermal Core | Euroclass A1 non-combustible stone wool slab (100-150 kg/m³) |
Detailed Technical Parameters & Testing
| Structural PU Tensile Strength | ≥ 3.0 MPa with 450% elongation at break |
|---|---|
| Pre-treatment & Cleaners | Isopropanol alcohol degreaser & chemical silane activator |
| Structural Spacer Tape | High-density open-cell double-sided structural spacer tape |
| Exterior Weather Sealant | 8018 Kalesilikon NS neutral alkoxy weatherproofing silicone |
| Thermal Transmittance Improvement | Eliminates thermal bridging; continuous envelope insulation |
| Acoustic Attenuation | Rw (C; Ctr) = 48 dB airborne sound reduction |
| Wind Load Capacity | Engineered for dynamic pressures exceeding 4.2 kN/m² |
Deployment, Building Codes & Verification
| Application Sectors | Modern airport terminals, educational campuses, high-rise office developments |
|---|---|
| Fire Safety Performance | Approved for high-rise buildings over 18m under UK Building Regs Part B |
| Certification | BBA / CWCT rainscreen test envelope compliance |
Specification & Trade Procurement
Initiate Trade Enquiry for CB-FC-0103 ↗
Request a Comprehensive Project Specification & Export Quotation
Cabivella supplies fully certificated, factory-engineered building materials directly from vetted production facilities in Türkiye to contractors, developers, and architects across the UK and Europe. Submit your bill of quantities or architectural schedule for an itemised quotation.
Factory-Direct Export
Direct dispatch from manufacturing plants in Istanbul, Izmir & Bilecik.
BS & EN Compliance
Fully certificated to UK Building Regs (Part B, Part L) & CE/EN norms.
Logistics Assurance
DAP / DDP job-site delivery with customs clearance handled by Cabivella UK.